How to use a microcomputer calorimeter

Read :
Release time : 2026-07-01

Pre-boot preparation

Before using the microcomputer calorimeter, check the appearance of the device to ensure that no parts are loose or damaged, and the power cord is firmly connected. After turning on the power supply, turn on the instrument switch and wait for the device to complete the self-test to check whether the display screen is normal and whether the function buttons are sensitive. At the same time, prepare the matching sample crucible, ignition wire, oxygen cylinder and other consumables to ensure that the oxygen purity meets the requirements, generally more than 99.5%.

Sample precision processing

Take an appropriate amount of sample to be tested and use a high-precision balance to accurately weigh it. The quality of the sample should be strictly within the range specified in the instrument manual, usually between 0.8-1 grams, and the weighing error should be controlled within ± 0.1 milligram. Put the weighed sample evenly into the crucible, and fix the two ends of the ignition wire on the electrode with tweezers to ensure that the ignition wire is in full contact with the sample to avoid poor contact and ignition failure.

parameter specification setting

Enter the instrument operation interface and set relevant parameters according to the sample type and testing requirements, including combustion time, ignition temperature, oxygen pressure, etc. Oxygen pressure is generally set at 2.8-3 MPa to ensure that the sample can be fully burned. After setting, carefully check the parameters and save the settings after confirming that they are correct to avoid affecting the accuracy of the test results due to parameter errors.

Detection operation flow



Put the crucible filled with the sample into the oxygen bomb of the calorimeter, and tighten the oxygen bomb cover to ensure a good seal to prevent oxygen leakage. Close the protective door of the instrument and click the "Start Detection" button, and the instrument will automatically complete the process of oxygenation, ignition, and detection. During the inspection process, do not touch the instrument at will. After the inspection is over, the instrument will automatically display and store the test results and record relevant data.

Final work after inspection

After the test is completed, close the oxygen cylinder valve first. After the pressure in the oxygen bomb is released, open the oxygen bomb cover, take out the crucible and clean the residue. Turn off the power supply of the instrument, clean the surface of the instrument, and keep the equipment tidy. Regularly calibrate and maintain the instrument to ensure that the instrument is always in good working condition and ensure the accuracy of subsequent test data.

Related News
View More >>
How much does the calorimeter cost in the brick factory? How much does the calorimeter cost in the brick factory?
07 .09.2026
The cost of calorimeter in brick factory is affected by multiple factorsFor a br
Which bituminous coal calorimeter is easy to use? Which bituminous coal calorimeter is easy to use?
07 .09.2026
In the field of coal detection, a bituminous coal calorimeter is a key equipment
Which Laiwu calorimeter is better? Which Laiwu calorimeter is better?
07 .09.2026
Laiwu is an important industrial town, and the demand for calorific value detect
How to read a calorimeter How to read a calorimeter
07 .09.2026
In many industries, such as energy, chemical, and food, calorimeters are the cor

Leave Your Message