Bandwidth evaluation automatic calorimeter
The bandwidth evaluation type automatic calorimeter is used for high-precision calorific value measurement of various solid and liquid substances in power, energy, petroleum, environmental protection. Food and scientific research departments, especially for the measurement of low calorific value combustible substances (fly ash, gangue, cement raw meal).
Adoption of standards:
GB/T 213-2008 "Method for determination of calorific value of coal"
GB/T 384-1981 "Determination of calorific value of petroleum products"
GB/T 30727-2014 "Method for determination of calorific value of solid biomass fuel"
GB/T 14402-2007 "Combustion properties of building materials and products - Determination of combustion calorific value"
GB/T 30991-2014 "General technical conditions for intelligent oxygen bomb calorimeter"
JC/T 1005-2006 "Method for determination of calorific value of cement black raw meal"
JJG 672-2018 "Oxygen bomb calorimeter verification regulations"
ASTM D5865-13 "Determination of calorific value of coal and coke"
ISO 1928:2009 "Determination of calorific value of solid fossil fuels"
CEN/TS 14918 "Determination of calorific value of solid biofuels"
BS EN 15400-2011 "Solid recovery fuel - calorific value test"
IS: 1350-1970 "Determination of coal and coke"
Performance features:
It has two structural forms, desktop and vertical, and can be freely selected according to the laboratory layout.
Large-capacity outer cylinder and water tank, with compressor cooling and heating functions to ensure constant water temperature and adapt to long-term continuous testing.
The quantitative water cup made of borosilicate glass with small volume change is used to ensure the stability of the water volume of the inner cylinder and the consistency of the test results each time.
Special oxygen bomb design (curved bottom), strong pressure resistance, shortened main period time.
The cooling calibration model is adopted to ensure the accuracy of the test results of high and low calorific value samples.
Automatic warning of sample weighing range; real-time monitoring of laboratory ambient temperature and humidity; automatic prompt of out-of-tolerance results.
Sample coding and weight information are automatically transmitted; test data can be backed up and uploaded; and experimental data is tamper-proof.
● It can achieve Orthrus management and record experimental process information.
Special features for fuel control:
1) If there are corruptive practices such as opening the lid and replacing the sample in the middle, the system will alarm and the experiment will be invalid;
2) Uploading data includes:
Environmental parameters: ambient temperature;
Process parameters: start time, ignition time, main period end time, main period temperature rise, cooling correction value C, etc.
Fault self-test: automatic lifting in place, automatic oxygenation in place, etc.
Test parameters: common method: 15min, fast method: 10min
2. Number of continuous test samples: unlimited
3. Outer cylinder constant temperature control mode: compressor
4. Precision: 0.10%
5. Heat capacity stability: 0.20% within one year
6. Structure: desktop/vertical
7. Inner cylinder water quantification method: glass quantitative water cup
8. Oxygen bomb number automatic identification
9. Inner cylinder filtration
10. Visible liquid level