1. After booting and resetting, automatically enter the function selection interface, and then press【▲】Or [▼】key selection"Settings"function,Press again[Confirm]Enter the setting function interface.

2.  press【▲】Or [▼】key selection"Optional settings"function,Press again[Confirm]Enter the optional setting interface.

3.  press【◄】or【►】Key to move the number of digits of the set value cursor, press【▲】or【▼】Key to set the value of temperature and time. The control temperature is set to (1~ 999) ℃, the temperature control time is set to (1~ 999) min. After the setting of process 1 is completed, press[Confirm]Enter the settings for the next process of the optional program. And so on, the optional program settings are shared20 processes to choose from. After the optional program setting is completed, press[Reset]End key, return to the optional program interface.

4.  After the optional program setting is completed, on the optional program interface, press[Confirm]Press the button to start the optional program for testing.

For example:Temperature control requirements600 ° C constant temperature for 30 minutes, and then rise to 700 ° C constant temperature for 25 minutes after not less than 40 minutes.

    1) Enter the "Optional Settings" interface.

The first stage is the heating stage: the time is set to 000 and the temperature is set to 600.

The second stage is the constant temperature stage: the time is set to 030 and the temperature is set to 600.

The third stage is the heating stage: the time is set to 040 and the temperature is set to 700.

The fourth stage is the constant temperature stage: the time is set to 025 and the temperature is set to 700.

6) Press[OK]Key to save;

修改尺寸 (1).jpeg


Related News
View More >>
How to read calorimeter data How to read calorimeter data
08 .30.2026
First, understand the basic data indicators of the calorimeterThe core data of t
What is the design principle of a calorimeter? What is the design principle of a calorimeter?
08 .30.2026
As a core instrument for accurately measuring heat, a calorimeter is widely used
What is the harm of lack of water in the calorimeter? What is the harm of lack of water in the calorimeter?
08 .30.2026
In all kinds of calorific value detection work, the calorimeter plays a crucial
What is the input interface of the calorimeter? What is the input interface of the calorimeter?
08 .30.2026
The central role of the calorimeter input interfaceThe input interface of the ca

Leave Your Message